 EMC filters
3-line filters for converters and power electronics Rated current 8 to 220 A
Series/Type: Date: B84143G*R110 January 2006
EPCOS AG 2006. Reproduction, publication and dissemination of this data sheet and the information contained therein without EPCOS' prior express consent is prohibited.
3-line filters for converters and power electronics
Power line filters for 3-phase systems Rated voltage 520/300 V AC, 50/60 Hz Rated current 8 to 220 A Alternative version
Series B84143A*R105
B84143G*R110
offers a low-cost solution. Construction
3-line filter Metal case Book size
Features

High insertion loss Optimized leakage current Space saving by optimized footprint Litz wires on the load side reduce mounting time Low weight Degree of protection: IP 201) Optimized for long motor cables and operation under full load Design complies with EN 133200, UL 1283, CSA C22.2 No.8 UL approval Applications
Frequency converters for motor drives, e.g.
elevators, pumps, traction systems, conveyor systems, HVAC systems (heating, ventilation and air conditioning) Wind farms Power supplies Terminals
Line side: Finger-safe terminal blocks Load side: Litz wires
Marking Marking on component: Manufacturer's logo, ordering code, rated voltage, rated current, rated temperature, climatic category, date code Minimum marking on packaging: Manufacturer's logo, ordering code
1) To IEC 60529
Please read Cautions and warnings and Important notes at the end of this document.
2
01/06
3-line filters for converters and power electronics
Typical circuit diagrams Filters for 8 ... 25 A
LINE L1
L2 L3
B84143G*R110
LOAD
L1' L2' L3'
SSB1286-Z
Filters for 36 ... 220 A
LINE L1 L2 L3 LOAD L1' L2' L3'
SSB1287-8
Please read Cautions and warnings and Important notes at the end of this document.
3
01/06
3-line filters for converters and power electronics
Technical data and measuring conditions Rated voltage VR Rated current IR Test voltage Vtest Overload capability (thermal) Leakage current Ileak Climatic category (IEC 60068-1) Approvals 520/300 V AC, 50/60 Hz
B84143G*R110
Referred to 40 C ambient temperature 1770 V DC, 2 s (line/line) 2700 V DC, 2 s (lines/case) 1.5 * IR for 3 min per hour or 2.5 * IR for 30 s per hour At 480 V AC, 50 Hz 25/100/21 (-25 C/+100 C/21 days damp heat test) UL 1283 for 480 V AC. For 520 V AC pending.
Characteristics and ordering codes VR AC IR Terminal cross section Ileak Line side: Load side: terminal litz blocks wires mm2 mA mm2 8 20 25 36 50 66 90 120 150 220 4 4 4 6 16 25 25 50 50 95 1.5 2.5 2.5 6.0 10 16 25 35 35 70 <6 <6 <6 < 16 < 16 < 16 < 16 < 16 < 16 < 16 Rtyp Approx. Ordering code weight Approvals (480 V)
V 520/300
A
m 40 10 10 5.2 2.4 1.8 1.2 1.0 0.7 0.4
kg 1.3 1.3 1.3 2.8 3.3 4.4 4.9 7.5 8.0 11.5 B84143G0008R110 x B84143G0020R110 x B84143G0025R110 - B84143G0036R110 x B84143G0050R110 x B84143G0066R110 x B84143G0090R110 x B84143G0120R110 x B84143G0150R110 x B84143G0220R110 x
x = approval granted
Please read Cautions and warnings and Important notes at the end of this document.
4
01/06
3-line filters for converters and power electronics
Dimensional drawings B84143G0008R110, B84143G0020R110, B84143G0025R110 (8 A to 25 A)
50 200 30010 Litz wire
B84143G*R110
80
40
31 15
0.5
1
Wire end ferrule Litz wire markings
PE M6 x 24 Terminal blocks 4 mm 2 Tightening torque 0.6 ... 0.8 Nm 230 2150.5
L1' L1 L2' L2 L3 Marking L3' PE PE LINE LOAD
250.3
SSB2188-F-E
6.5
250
B84143G0036R110 (36 A)
60 40010
Litz wire
150
75
60 30
0.5
1
Wire end ferrule Litz wire markings
PE M6 x 24 Terminal blocks 6 mm 2 Tightening torque 1.5 ... 1.8 Nm 280 2650.5
L1 L2 Marking L3 PE LINE LOAD L1' L2' L3' PE
46
6.5
350.3
SSB2190-R-E
Please read Cautions and warnings and Important notes at the end of this document.
5
01/06
56
3-line filters for converters and power electronics
B84143G0050R110 (50 A)
60 300 50010 Litz wire
B84143G*R110
150
75
52
30
0.5
PE M6 x 24 330
1
Wire end ferrule Litz wire markings
L1 L2 Marking L3 PE LINE LOAD
L1' L2' L3' PE
6.5
50010 Litz wire
Terminal blocks 16 mm 2 Tightening torque 2 ... 2.3 Nm
3150.5
350.3
SSB2191-Z-E
B84143G0066R110, B84143G0090R110 (66 A and 90 A)
80 300
150
75
52 30
0.5
1
56
60 Wire end ferrule Litz wire markings
PE M10 x 39 Terminal blocks 25 mm 2 Tightening torque 4 ... 4.5 Nm 330 3150.5
6.5
L1' L2' L3' PE
L1 L2 Marking L3 PE LINE LOAD
550.3
SSB2192-8-E
Please read Cautions and warnings and Important notes at the end of this document.
6
01/06
76
3-line filters for converters and power electronics
B84143G0120R110, B84143G0150R110 (120 A and 150 A)
90 350
B84143G*R110
50010 Wire end ferrule
Litz wire
200
100
78
0.5
40
1
PE M10 x 39 Terminal blocks 50 mm 2 Tightening torque 6 ... 8 Nm
65 380 3650.5 Litz wire markings
6.5 650.3 50010 Litz wire
0.5 1
SSB2194-P-E
L1 L1' L2 Marking L2' L3 L3' PE LINE LOAD PE
B84143G0220R110 (220 A)
110 400 Wire end ferrule
220
110
30
79
86
PE M10 x 39 Litz wire markings Terminal blocks 95 mm 2 Tightening torque15 ... 20 Nm 430 4150.5
6.5
80
L1 L2 Marking L3 PE LINE LOAD
L1' L2' L3' PE
850.3
SSB2196-6-E
Please read Cautions and warnings and Important notes at the end of this document.
7
01/06
106
3-line filters for converters and power electronics
Insertion loss (typical values at Z = 50 ) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) Filters for 8 A
120 dB B84143G0008R110 100
SSB1288-G
B84143G*R110
Filters for 20 and 25 A
120 dB B84143G0020R110 B84143G0025R110
SSB1289-P
100
80
80
60
60
40
40
20
20
0 10 4
10 5
10 6
10 7
Hz 10 8 f
0 10 4
10 5
10 6
10 7
Hz 10 8 f
Filters for 36 ... 220 A
120 dB B84143G0036 ... G0220R110 100
SSB1290-S
80
60
40
20
0 10 4
10 5
10 6
10 7
Hz 10 8 f
Please read Cautions and warnings and Important notes at the end of this document.
8
01/06
EMC filters Cautions and warnings
Important information Please read all safety and warning notes carefully before installing the EMC filter and putting it into operation (see ). The same applies to the warning signs on the filter. Please ensure that the signs are not removed nor their legibility impaired by external influences. Death, serious bodily injury and substantial material damage to equipment may occur if the appropriate safety measures are not carried out or the warnings in the text are not observed. Using according to the terms The EMC filters may be used only for their intended application within the specified values in lowvoltage networks in compliance with the instructions given in the data sheets and the data book. The conditions at the place of application must comply with all specifications for the filter used. Warnings
It shall be ensured that only qualified persons (electricity specialists) are engaged on work such

as planning, assembly, installation, operation, repair and maintenance. They must be provided with the corresponding documentation. Danger of electric shock. EMC filters contain components that store an electric charge. Dangerous voltages can continue to exist at the filter terminals for longer than five minutes even after the power has been switched off. The protective earth connections shall be the first to be made when the EMC filter is installed and the last to be disconnected. Depending on the magnitude of the leakage currents, the particular specifications for making the protective-earth connection must be observed. Impermissible overloading of the EMC filter, such as impermissible voltages at higher frequencies that may cause resonances etc. can lead to destruction of the filter housing. EMC filters must be protected in the application against impermissible exceeding of the rated currents by suitable overcurrent protective.
9
01/06
EMC filters Important notes
The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of passive electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of a passive electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of a passive electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as "hazardous"). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the "General Terms of Delivery for Products and Services in the Electrical Industry" published by the German Electrical and Electronics Industry Association (ZVEI). 7. The trade names EPCOS, EPCOS-Jones, Baoke, CeraDiode, CSSP, MLSC, PhaseCap, PhaseMod, SIFI, SIKOREL, SilverCap, SIMID, SIOV, SIP5D, SIP5K, UltraCap, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks.
10
01/06


▲Up To Search▲   

 
Price & Availability of B84143G0220R110

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X